Liu Jing, Xu Guocheng, Shi Yanli, Zhou Guanghao, Gu Xiaopeng. Rapid ultrasonic C-scan test for spot welding based on image interpolationJ. CHINA WELDING, 2014, 23(4): 37-43.
Citation: Liu Jing, Xu Guocheng, Shi Yanli, Zhou Guanghao, Gu Xiaopeng. Rapid ultrasonic C-scan test for spot welding based on image interpolationJ. CHINA WELDING, 2014, 23(4): 37-43.

Rapid ultrasonic C-scan test for spot welding based on image interpolation

  • In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan image generated cannot be used to assess spot welding quality reliably. Based on bicubic image interpolation, the C-scan image in low resolution with the large step length 1 000 μm is subdivided and reconstructed. By this means, the C-scan image resolution is greatly enhanced and testing results obtained are satisfactory, realizing rapid assessment of spot welds. The results of rapid ultrasonic C-scan test fit the actual metallographic measured value well. Mean value of normal distribution of error statistics is 0.006 67, and the standard deviation is 0.087 11. Rapid ultrasonic C-scan test based on image interpolation is of high accuracy and excellent stability.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return